Technical Specifications

We are a platform and data management company, and will match the proper instrument with the data requirements and available fishing in the region of relevance. Baseline specifications are listed below; however, we are always looking to expand the suite of parameters which can be measured from fishing vessels and gears.

Temperature/Depth Profiling ZebraTech Moana TD

Temperature

  • Operating range: -2 DegC to 35 DegC
  • Initial accuracy: +/- 0.05 DegC
  • Resolution: 0.001 DegC
  • Response rate: 1 second time constant

Pressure

  • Calibrated range
    • TD200: 0 to 200m
    • TD1000: 0 to 1000m
  • Initial accuracy: +/- 0.5% or less full scale across operating temperature range
  • Resolution: 0.1m

Surface Weather Station

  • Air Temp Accuracy: ±1.1°C at 20°C
  • Air Temp Resolution: 0.1°C
  • Barometric Pressure Accuracy: ±0.5 hPa at 25°C
  • Barometric Pressure Resolution: 0.1 hPa
  • Theoretical Wind Speed and Direction: Yes
  • True Wind Speed and Direction: Yes
  • Wind Direction Accuracy: ±3° at 10 m/s
  • Wind Direction Resolution: 0.1°
  • Wind Speed Accuracy: 5% at 10 m/s at 4 angles
  • Wind Speed Resolution: 0.1 m/s